Status of the ECR ion source for TRIAC

Nakanoya, Takamitsu; Matsuda, Makoto; Fujii, Yoshio*

Proceedings of 2nd Annual Meeting of Particle Accelerator Society of Japan and 30th Linear Accelerator Meeting in Japan, p.729 - 730, 2005/07

TRIAC (Tokai Radioactive Ion Accelerator Complex) facility can accelerate both radioactive and stable ion beams up to 1.1Mev/u. In this facility, an ECR ion source is used for production of stable ion beams. Stable ion beams are used mainly as a pilot beam for radioactive ion beam. ECR ion source is required to produce many kinds of ion species, not only gas state elements. So, we developed a high temperature oven for obtaining metal ion beams. This paper describes the design and detail of the oven and experimental results.

JAEA Reports

Surface level measurement method of a liquid cesium with float with marker magnet for cesium feeding system in the negative ion source

Ito, Takao; Yamazaki, Haruyuki*; Usui, Katsutomi; Mogaki, Kazuhiko; Kuriyama, Masaaki

JAERI-Tech 99-066, p.13 - 0, 1999/09

JAERI-Tech-99-066.pdf:0.6MB

no abstracts in English